Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
Search Results "Maximum Reach Depth"
-
11B-306.3.4 Clearance reduction
-
19 Inch Low Height
19 Inch Low Height Although the subcommittee’s conversations were complex and far-reaching, the following points summarize the factors that lead to the selection of the 19 inch height...
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
When door vision lights are limited to 100 square inches by the fire code, is compliance with the specified maximum height of 43” to the bottom edge still required?
Yes. The Standards do not exempt such doors from the requirement for vision lights (§404.2.11). However, compliance is not required when the lowest part of the vision light is more...
-
2. Equipment Clearances for Breast Platforms
The proposed rule included a requirement that 17 inches minimum and 25 inches maximum of the 48-inch wheelchair space depth include knee and toe clearance....
-
Salsbury Industries See Through Metal Locker Six Tier Box Style Bridge 16 Box
Requires the Registered User plan or above. Login!
-
Re: Slope of R309 On-Street Parking Spaces
The more level they are, the more usable they will be, but a 2.08% maximum slope is not a requirement. Verified by Melissa Anderson at APA conference 2/2/18...
-
11B-805 Medical care and long-term care facilities
Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
- Kompan, Inc. Miram GXY926
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
-
309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in 308....
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
-
Dispensers: ADA Standard Section 604.9.6
Section 604.9.5 covers the current ADA Standards for dispensers in children's use toilet compartments.
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....