1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope....
Search Results "Curb Ramp Width"
Commonly Searched Documents
-
1.2.7
-
1009.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1012....
-
WILLITS, et al v. CITY OF LOS ANGELES - Settlement Terms
Willits v. City of Los Angeles Term Sheet as of March 30, 2015
-
WILLITS, et al v. CITY OF LOS ANGELES - Settlement Agreement and Release of Claims
UNITED STATES DISTRICT COURT CENTRAL DISTRICT OF CALIFORNIA CASE NO. CV 10-5782 CBM (RZx) SETTLEMENT AGREEMENT AND RELEASE OF CLAIMS MARK WILLITS, JUDY GRIFFIN,...
-
11B-250 Circulation paths
[See subsections ...]
-
§ 38.159(c)(8) Handrails
to grasp them from outside the vehicle while starting to board, and to continue to use them throughout the boarding process, and shall have the top between 30 inches (760 mm) above the ramp...
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
405.7.1 Slope. Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
4.8.5(4)
(4) Gripping surfaces shall be continuous.
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings.
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
Passenger Loading Zones [4.6.6]
Aisles must be at least 5 feet wide, although a wider aisle (8 feet wide minimum) is helpful at zones that serve transit vehicles with lifts or ramps....
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
(1)(e)
(e) Doorways on the end of the enclosure, opposite the water closet, should have a minimum clear opening width of 32 inches (815 mm)....
-
B5. Curb Ramp
Is a curb ramp provided between the vehicle pull up area and the access aisle (see figure above) or the access aisle and the accessible route (see figure on page 9) to the accessible entrance...
-
§ 38.95(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
Measuring Door Openings
This measures the clear width of the door opening through which people pass, which is less than the width of the door itself....
-
1017.2 Aisles in assembly spaces
1017.2 Aisles in assembly spaces. Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1028.