Comment. In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2). This specification stems from the...
Search Results "Curb Ramp Width"
Commonly Searched Documents
-
Doorways
-
G1
G1. Is there an accessible route, at least 36 inches wide, that connects each sleeping area with other shelter activity areas? Yes No Note: it may narrow to 32 inches...
-
Accessible Route [9.2.2(2)]
Accessible Route [9.2.2(2)] An accessible route at least 36 inches wide must be provided to all accessible elements, including phones and thermostats, provided for use by room...
-
Passing Space [§403.5.3]
Passing Space [§403.5.3] Passing space is required every 200 feet and must be provided as a 60” by 60” minimum space or as T-shaped space where each stem is at least 48”...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if...
-
Recreational Boating Facilities: ADA Standard Section 206.2.10
Section 206.2.10 covers scoping requirements in the most current ADA Standards for accessible routes to recreational boating facilities
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an area...
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope....
-
Clearances: ADA Standard Section 403.5
Section 403.5 covers the current ADA Standards for clearances on walking surfaces that are part of an accessible route.
-
11B-502.2 Vehicle spaces
Car parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent...
-
11B-502.2 Vehicle spaces
Car parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent...
-
11B-206.2.10 Recreational boating facilities
Boat slips required to comply with Section 11B-235.2 and boarding piers at boat launch ramps required to comply with Section 11B-235.3 shall be on an accessible route....
-
§ 38.83(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches, with a safety factor...
- How to Measure Ramp Handrail Extensions
-
Extensions
Handrails that are not continuous must have horizontal extensions at both the top and bottom of the ramp at least 12 inches long that are rounded or returned smoothly to walls, posts, or...
-
C. Doors
described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within guestrooms allow at least 32" clear passage width...
-
502.2 Vehicle Spaces
Each parking space must be at least 12 feet (3658 mm) wide shall be marked to define the width, and shall have an adjacent access aisle complying with 502.3....
-
Accessible Parking Spaces for Cars
Accessible parking spaces for cars have at least a 60-inch-wide access aisle located adjacent to the designated parking space. The access aisle is just wide enough to permit a person...
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides....
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side....
-
11B-502.2 Vehicle spaces
Car parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent...
-
T205.1 General
Non-rail vehicles shall provide illumination complying with T503 at ramps, bridgeplates, doorways, and boarding and alighting areas....
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?