A level landing 4 feet (1219 mm) deep shall be provided at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or...
Search Results "Sloped Entry"
Commonly Searched Documents
-
1127B.5, Item 4
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
10 - foot straightedge method
The same problem exists when measuring slope. There is no way to measure a localized slope that may actually be greater than the overall slope of the straightedge....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level....
-
608.2.2 Standard Roll-In Type Shower Compartments
30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry...
-
Getting In
Building entries must be flush with the grade of the outside access route and have a beveled doorsill that is not more than one-half inch high....
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
- Kompan, Inc. Elements Play Structures Tower ELE400050
-
RAMP
A walking surface in an accessible space that has a running slope greater than 1:20....
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
608.2.3 Alternate Roll-In Type Shower Compartments
A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
11B-608.2.3 Alternate roll-in type shower compartments
A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
- TownSteel TDG129 Door Guard
-
9.a [§ 4.7.5]
To answer this question you need to determine the slope of the flared sides to make sure it is 10 percent or less....
-
405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this chapter....
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
Depending on the width of the hallway and other circulation issues, it can be preferable to swing the entry door into the toilet room....
-
Accessible Route to Play Components
The technical requirements at section 1008 include provisions where if three or fewer entry points are provided to a soft contained play structure, then at least one entry point must be...
-
P. MAINTENANCE OF ACCESSIBLE FEATURES AND TRAINING
Within nine (9) months of the entry of this Consent Decree, the County will submit for pre-approval by the United States a proposed training program, lasting at least four hours, on the...