To measure the slope of the curb ramp’s flared side, place a level on the flared side near the edge of the curb. The level should be placed so that it is parallel to the curb....
Search Results "Sloped Entry"
Commonly Searched Documents
-
9.b [§ 4.7.5]
-
402 Accessible Routes
Walking surfaces must have a running slope of 1:20 or less. Those portions of accessible routes that slope more than 1:20 must be treated as ramps or curb ramps. Comment....
-
B. Interior Ramps
(3) Third Floor North Corridor (Route to Fitness Center, Pool, and Spa) - This corridor will be modified so that its running slope does not exceed 1:20 (5%) or 1:12....
-
1.1.1 Measurement tools
Angular or slope measuring devices should be capable of measuring to a precision of 0.1 degree and elevation measuring devices should be capable of measuring to a precision of 0.01 ft (1...
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
GANGWAY
[DSA-AC] A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this code....
-
§ 382.40a Boarding assistance for large aircraft
operations with aircraft having a seating capacity of 31 or more passengers at airports with 10,000 or more annual enplanements, in any situation where passengers are not boarded by level-entry...
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level. ...
-
11B-608.2.1 Transfer type shower compartments
shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914 mm) wide minimum entry...
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
Parking Spaces for Vehicles Other Than RVs [F244.2.3.2.2]
Parking spaces for vehicles other than RVs within camping units with mobility features must comply with the following technical requirements for width, surface, and slope....
-
1(3)(b)
(b) An elevated walkway is planned between a building entrance and a vehicular or pedestrian arrival point and the planned walkway has a slope no greater than 10 percent....
-
§35.151(e)(2)
(2) Newly constructed or altered street level pedestrian walkways must contain curb ramps or other sloped areas at intersections to streets, roads, or highways....
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
§ 35.151(i)(2)
(2) Newly constructed or altered street level pedestrian walkways must contain curb ramps or other sloped areas at intersections to streets, roads, or highways....
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level. Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances...
-
804.2.1 Pass Through Kitchen
Pass through kitchens shall have two entries. Figure 804.2.1 Pass Through Kitchens...
-
11B-608.2.3 Alternate roll-in type shower compartments
A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
M305.3.1.2 Diagnostic Equipment Containing a Wheelchair Space
On diagnostic equipment containing wheelchair spaces with one entry that also serves as the exit, the length of the gripping surface of horizontal standing supports shall be equal to or...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
E. GRIEVANCE PROCEDURE
Within three (3) months of the entry of this Consent Decree, the County will adopt the attached ADA Grievance Procedure, Attachment C, distribute it to all of its agencies, post it...
-
Door Closers [4.13.10]
Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be slow enough to allow entry...
-
Press Boxes [§206.2.7]
field or assembly area is no more than 500 sq. ft. if press boxes are either: free-standing and elevated above grade at least 12’ or located in bleachers with points of entry...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....