Search Results "Sloped Entry"
Commonly Searched Documents
- Door King Inc. 1837 PC Programmable IM Server Overview
- Whitehall Mfg. Ligature Resistant Solid Surface Basin
- Whitehall Mfg. Ligature-Resistant Box with Hydraulic Flush Valve for Top Supply ADA Toilet
- American Standard Ovalyn™ Universal Access Undercounter Sink
- Magnuson Group UMEA Waste Receptacles
-
Employee Work Area - Reasoning Behind Code?
Why not just require “approach, entry & exit” like other EWAs?...
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries. FIGURE 11B-804.2.1 PASS THROUGH KITCHENS...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
11B-208.3.3.2
An accessible route from the residential dwelling unit's primary entry door to the vehicular entrance at the garage....
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level....
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension "x" in Fig. 25) if the door is at...
-
Q17. Does the ADA require that service animals be certified as service animals?
Covered entities may not require documentation, such as proof that the animal has been certified, trained, or licensed as a service animal, as a condition for entry....
-
E. GRIEVANCE PROCEDURE
Within three (3) months of the entry of this Consent Decree, the County will adopt the attached ADA Grievance Procedure, Attachment C, distribute it to all of its agencies, post it on its...
-
§ 38.73(d)(1) Requirements
The design of level-entry vehicles shall be coordinated with the boarding platform or mini-high platform design so that the horizontal gap between a vehicle at rest and the platform shall...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area at the exterior side of the primary entry door and any required exit doors shall comply with Section 1126A....
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2....
-
3a.
If yes, is a ramp or sloped hallway provided? Yes _____ No _____ If yes, go to question E1-4. Note: A ramp, lift, or elevator can be used to provide access to floor levels....
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
platform will be moved to 34 inches above the ground, and then the clearance dimensions will be measured just as they would be on any stationary piece of equipment, with allowance for slopes...
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
RV Parking Spaces Within Camping Units With Mobility Features and RV Pull-Up Spaces at Dump Stations [F244.2.3.2.1 and F244.4]
RV parking spaces within camping units with mobility features and RV pull-up spaces at dump stations must comply with the technical requirements for width, surface, and slope of RV spaces...
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions. ...
-
A4.8.4 Landings
Level landings are essential toward maintaining an aggregate slope that complies with these guidelines....