Search Results "Sloped Entry"
Commonly Searched Documents
-
Accessible Route
- Mega Jailhouse Vandal Resistant Hooded Toilet Paper Holder with Locking Mechanism
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing. ...
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical....
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
§ 36.304(d)(3)(ii)
least 300 linear feet of swimming pool wall, it shall comply with the applicable requirements for swimming pools, except that it shall be required to provide only one accessible means of entry...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
A4.3.11.4 Two-way Communication
requirement could be satisfied with something as simple as a button in the area of rescue assistance that lights, indicating that help is on the way, when the message is answered at the point of entry...
-
Can platform lifts be locked?
The Standards require “unassisted” entry and exit from lifts (§410.1)....
-
§ 38.161 Moveable aisle armrests
including all moveable or removable seats at wheelchair or mobility aide securement locations, shall have an armrest on the aisle side which can be raised, removed, or retracted to permit easy entry...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
- Reese Enterprises, Inc. PERFEC MATv * Aluminum Hinge
-
Transition Plate
A sloping pedestrian walking surface located at the end(s) of a gangway....
-
106.5.72 Transition Plate
A sloping pedestrian walking surface located at the end(s) of a gangway....
-
HANDRAIL
A horizontal or sloping rail intended for grasping by the hand for guidance or support....
-
HANDRAIL
A horizontal or sloping rail intended for grasping by the hand for guidance or support....
-
Work Areas [4.1.1(3)]
Work areas must be accessible for "approach, entry, and exit," which means location on an accessible route so that people using wheelchairs can enter and back out of the space....
-
F. GENERAL EFFECTIVE COMMUNICATION PROVISIONS
Within three (3) months of the entry of this Consent Decree, the County will identify sources of qualified sign language and oral interpreters, qualified readers, real-time transcription...
-
B. NOTIFICATION
Within thirty (30) days of the entry of this Consent Decree, the County will adopt and follow the attached Notice under the Americans with Disabilities Act, Attachment A (“Notice”); distribute...
-
F. GENERAL EFFECTIVE COMMUNICATION PROVISIONS
Within three (3) months of the entry of this Consent Decree, the County will identify sources of qualified sign language and oral interpreters, qualified readers, real-time transcription...
-
§382.95(b)
boarding and deplaning assistance through the use of lifts or ramps at any U.S. commercial service airport with 10,000 or more annual enplanements where boarding and deplaning by level-entry...
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...