[DSA-AC] A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility....
Search Results "Sloped Entry"
-
CLOSED-CIRCUIT TELEPHONE
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
CLOSED-CIRCUIT TELEPHONE
[DSA-AC] A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility....
-
11B-1008.4.5 Transfer supports
Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided....
-
1. Start with Comprehensive Planning and Site Selection
The accessible route must be designed as the main pedestrian route and connect all accessible equipment, both points of entry and egress....
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
Nosings: ADA Standard Section 504.5
Section 504.5 covers the current ADA Standards for stair nosings.
- Lift-U® Fold-Out Ramp Plus
-
Top Landing [§406.4]
Side flare slopes cannot exceed 1:10 max. (or 1:12 max. in alterations where a top landing is unavailable)....
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis) Parallel curb ramps have a running slope that is in-line with the direction of sidewalk travel and lower the sidewalk to a level...
-
1016.1 General
access routes, passing spaces, and resting intervals (1016.2); the clear width of outdoor recreation access routes (1016.3); passing spaces (1016.4); obstacles (1016.5); openings (1016.6); slopes...
-
Closed-Circuit Telephone
A telephone with a dedicated line such as a house phone, courtesy phone or phone that must be used to gain entry to a facility....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
The point of entry to the equipment is in the center. The length of the stretcher means a patient would transfer on in the middle....
-
Technical Requirements [1017]
The technical requirements for trails include specific provisions for the surface, clear tread width, passing spaces, tread obstacles, openings, running slope, cross slope, resting intervals...
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
QUESTION: WHEN DO THE REQUIREMENTS OF SECTION 37.42 BEGIN TO APPLY?
ANSWER: The performance standard and other requirements of section 37.42(a) apply to stations that are approved for entry into final design or that begin construction or alteration...
-
221.2.3.2 Vertical Dispersion
In bleachers, wheelchair spaces shall not be required to be provided in rows other than rows at points of entry to bleacher seating. Advisory 221.2.3.2 Vertical Dispersion....
- Door King Inc. 1515 Digital Lock Smart Open APP
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...