Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....
Search Results "Expected Maximum Flight Duration"
Commonly Searched Documents
-
Exterior/ Fire Doors
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the transfer...
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
407.8.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach Reach Depth Operable Part Height Less than 20 inches (510 mm) 48 inches (1220 mm) maximum...
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
407.12.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
- Stanley SB600 Bifolding Door
-
Accessible Slopes
For the cross slope of an accessible route the maximum slope allowed is 1:48....
-
404.2.9 Door and Gate Opening Force
Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum....
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
404.2.9 Door and Gate Opening Force
Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum....
-
T302.3 Openings
Wheelchair securement system components affixed to walking surfaces shall be permitted to have openings 7/8 inch (22 mm) maximum in width provided that, where such openings are more than...
-
407.12.2 Side Reach (Section-by-Section Analysis)
It proposes to limit the height of the portion of the ICT over which a person must reach to access controls to 34 inches maximum in height....
-
Grade (R302.5) (Section-by-Section Analysis)
route is permitted to equal the general grade established for the adjacent street or highway, except that where pedestrian access routes are contained within pedestrian street crossings a maximum...