Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
Search Results "Expected Maximum Flight Duration"
Commonly Searched Documents
-
11B-603.4 Coat hooks, shelves and medicine cabinets
-
Passing Spaces: ADA Standard Section 403.5.3
Section 403.5.3 covers the current ADA Standards for passing spaces that are part of an accessible route.
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....
-
1607A.9.2 Grab bars, shower seats and accessible benches
designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower seat, or seat of the accessible bench so as to produce the maximum...
- Guldmann GH3+ Lifting Module with Scale
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
Ramps
For each elevated ramp run: 12-inch (305 mm) maximum rise 1:12 maximum slope 36-inch (915 mm) minimum clear width ...
- Stanley SB600 Bifolding Door
- Allegion Von Duprin 98/99 Series AX Intro Video
-
B. Effective Communication
The determination of appropriate Auxiliary Aids or Services, and the timing, duration, and frequency with which they will be provided, will be made by the MSHA hospital personnel in consultation...
- Easterseals Superior California
- Jackson Center for Independent Living (JCIL) - Jackson, TN
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of...
-
T302.4 Surface Discontinuities
Surface discontinuities shall be ½ inch (13 mm) high maximum and shall be beveled with a slope not steeper than 1:2. EXCEPTIONS: 1....
-
705.1.1 Dome Size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
2. The specific risk must be identified
identified If an individual has a disability, the employer must identify the aspect of the disability that would pose a direct threat, considering the following factors: the duration...
-
‘‘direct threat’’
must be based on an individualized assessment, based on reasonable judgment that relies on current medical evidence or on the best available objective evidence, to determine: the nature, duration...
-
Perpendicular Curb Ramps (R304.2) (Section-by-Section Analysis)
A maximum slope of 10 percent is specified for the flared sides of perpendicular curb ramps where a pedestrian circulation path crosses the curb ramp....
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above...
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...