Specifications are provided for various means of providing pool access, including pool lifts, sloped entries, transfer walls, transfer systems, and stairs....
Search Results "Aisle Stair"
Commonly Searched Documents
-
1009 Swimming Pools, Wading Pools, and Spas
-
Can accessible spaces be parallel instead of perpendicular?
instead of parallel, but perpendicular parking spaces are preferred at facilities located on sites because most allow users to park facing in or out depending on the side that the access aisle...
-
4.1.6(1)(f)
(f) If an escalator or stair is planned or installed where none existed previously and major structural modifications are necessary for such installation, then a means of accessible vertical...
-
11B-221.2.1.5 Stadium-style movie theaters
The required wheelchair spaces shall be located on risers or cross-aisles in the stadium section that satisfy at least one of the following criteria: Located within the rear 60 percent...
-
Advance Notice Only for Particular Services and Equipment
[Secs. 382.33(b)(5)-(8)] Example: While making his reservation, a passenger with a disability gave the reservation agent 48 hours’ advance notice that he would need an aisle chair...
-
1. Typical Issues
Accessible parking spaces need an adjacent access aisle that provides space for a person with a mobility disability to exit their vehicle....
-
Handrails Requirement
Requirements for handrails in the proposed rule applied only to those provided along ramps and stairs....
-
§ 38.29(e)
(e) For vehicles in excess of 22 feet in length with front-door lifts or ramps, vertical stanchions immediately behind the driver shall either terminate at the lower edge of the aisle-facing...
-
Railings—Guardrails, Handrails, and Safety
While the accessibility guidelines for outdoor recreation areas do not require handrails at stairs, consider the safety of the people using the stairs and the setting when deciding whether...
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
Circulation Path
The components of a circulation path include but are not limited to rooms, corridors, doors, stairs, smokeproof enclosures, horizontal exits, ramps, exit passageways, escalators, moving...
-
Areas of Refuge (Preamble, Section-by-Section Analysis)
- Areas of refuge (areas with direct access to a stairway, and where people who cannot use stairs may await assistance during a emergency evacuation) will be required, as proposed, but the...
-
Steps
ADAAG does not specify the minimum number of steps that comprise a set of "stairs." Most building codes require handrails for a certain change in level or number of steps....
-
Areas of Refuge (Section-By-Section Analysis and Response to Comments)
- Areas of refuge (areas with direct access to a stairway, and where people who cannot use stairs may await assistance during a emergency evacuation) will be required, as proposed, but the...
-
Section 4.1.3, Accessible Buildings: New Construction (Preamble, Section-by-Section Analysis)
Sections 4.1.3 (1) through (4) cover accessible routes, protruding objects, ground and floor surfaces, and stairs....
-
Section 4.1.3, Accessible Buildings: New Construction (Section-By-Section Analysis and Response to Comments)
Sections 4.1.3 (1) through (4) cover accessible routes, protruding objects, ground and floor surfaces, and stairs....
-
1002.1 Definitions
STAIR. STAIRWAY. WINDER...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
The ADA Standards apply requirements for stairways to each stair that is part of a required means of egress (§210). Exit Stairway Enclosures...
-
1002.1 Definitions
STAIR. STAIRWAY. WINDER...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
Laundry Room
Elevated water saving washer and elevated dryer with front-mounted controls Recycling bins and composter (eliminating the need for a garbage disposal) LED tread lights on all stairs...