Search Results "Exit Ramp"
Commonly Searched Documents
-
Re: 703 Signs
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Re: 216 Signs
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
TERMS OF SETTLEMENT
operable working condition on Election Day those features of facilities and equipment (including permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps...
-
Accessible Routes
Accessible boat slips, accessible boarding piers at boat launch ramps,and other accessible spaces and elements within a boating facility must also be connected by an accessible route....
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
Visual Characters: ADA Standard Section 703.5
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 and are accompanied by Braille complying with Section...
-
C. Boarding and Deplaning Assistance
[Sec. 382.39(a)] The type of assistance you must offer includes, as needed, services personnel and the use of wheelchairs, ramps, or mechanical lifts....
-
Jeanne Halloin, IES. Existing Standards and Design Guidance
Entrances (slides 3 and 4) Additional comments: Need better signage at entrances Handle locations should be consistent Ramps (slide 5) Route of Travel...
-
4.1.7(1)(a)
(a) As a general rule, the accessibility provisions of part 4 shall be applied to "qualified" historic buildings and facilities. "Qualified" buildings or facilities are those...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. Stroke...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms). Letters and numerals shall be raised 1/32 in, upper case, sans serif or simple serif type and shall be...
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
4.1.2(15)
(15) If signs are provided, they shall comply with 4.30.1, 4.30.2 and 4.30.3. In addition, permanent signage that identifies rooms and spaces shall also comply with 4.30.4 and...
-
4.30.4* RAISED CHARACTERS OR SYMBOLS
Letters and numbers on signs shall be raised 1/32 in (0.8 mm) minimum and shall be sans serif characters. Raised characters or symbols shall be at least 5/8 in (16 mm) high, but no...
-
11B-703.4 Installation height and location
11B-703.4 Installation height and location. Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
11B-703.5.7 Stroke thickness. Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7...