Terry, You should identify the minimum dimensions of the clear floor space at the Lav.
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
Clear floor space at Lav
-
Clear Ground Space [1011.2]
Size [1011.2.1]—The size of the clear ground space is based on the dimensions for maneuvering clearance in section 305.7 of the ABA Standards for clear ground spaces that are confined on...
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within...
-
5.5 Food Service Lines
Food service lines shall have a minimum clear width of 36 in (915 mm), with a preferred clear width of 42 in (1065 mm) to allow passage around a person using a wheelchair. Tray...
-
5.2 FOOD SERVICE LINES
Food service lines shall have a minimum clear width of 36 in (915 mm), with a preferred clear width of 42 in (1065 mm) where passage of stopped wheelchairs by pedestrians is desired....
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed to place the requirements for stirrups on diagnostic equipment used by patients in the supine, prone, or side-lying position in M301....
-
M301.3.1 Transfer Supports
Transfer supports shall be provided for use with the transfer sides required by M301.2.3 and shall comply with M305.2....
-
5.2.1.1 Transfer Surface Width Recommendations for M301
5.2.1.1 Transfer Surface Width Recommendations for M301 The Committee recommends a transfer surface of 28 inches minimum width for equipment used by patients in a supine, side-lying,...
-
T208 Passenger Access Routes
[See subsections ...]
-
1133A.7, Item 3
3. A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm).
-
Grab Bars
Grab bars are usually provided in buildings to provide stability and allow people to use their arms to assist in movement over short distances. The most common location for grab bars...
-
1133A.7, Item 3
3. A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm).
-
§ 38.83(c)(8) Handrails
(8) Handrails. If provided, handrails shall allow persons with disabilities to grasp them from outside the vehicle while starting to board, and to continue to use them throughout the...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they...
-
7(1)(c)
(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that...
-
11B-608.2.2.1 Clearance
[2010 ADAS] 608.2.2.1 Clearance....
-
11B-1002.4.4 Clearances
Clearances for wheelchair spaces shall comply with Section 11B-1002.4.4. Exceptions: Where provided, securement devices shall be permitted to overlap required clearances....
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1....
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches....
-
7(2)(a)
allow a parallel approach by a person in a wheelchair; if parallel approach is not possible within the space, any cabinets provided would have to be removable to afford the necessary knee clearance...