Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door....
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
11B-804.6.5.2 Bottom-hinged door ovens
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door....
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door....
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2 Description: This provision prescribes a cross-sectional profile of the transfer support...
-
Three Additional Features for Van-Accessible Parking Spaces
seen when a vehicle is parked in the space 96" min. width access aisle, level (max. slope 1:50 in all directions), located beside the van parking space Min. 98-inch-high clearance...
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
K3
K3. In each eating area, if tables with fixed seats are provided, do at least 5% of each type of table with fixed seats have accessible locations with knee space at least 27 inches...
-
1133A.2.1, Item 1
1. U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm). (See...
-
4.24.5 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach. The clear floor space shall be on...
-
4.24.5 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach. The clear floor space shall be on...
-
1133A.2.1, Item 1
1. U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm). (See...
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
M301.3.2 Stirrups
M301.3.2 Stirrups Proposed requirement: Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs. • Sub-committee...
-
Plan 6B: 12-Foot Wide Accessible Guest Room
is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16 inches from side wall (section 604.2); and • No other fixtures or obstructions...
-
11B-805 Medical care and long-term care facilities
Knee clearance requirement - All accessibility requirements of Section 11B-606 apply to lavatories, sinks, and handwashing fixtures required to be accessible....
-
Plan 4B: 13-Foot Wide Accessible Guest Room
• Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space includes knee and toe clearance...
-
Plan 3B: 12-Foot Wide Accessible Guest Room
• Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space includes knee and toe clearance...
-
Entrances
provide a minimum width of 32 inches and there must also be enough room for a person using a wheelchair to maneuver to open the door, including 18 inches of clear space beyond the latch side...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where patients lie in a supine, prone, or side-lying...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...