Search Results "Hinge Side Clearance"
Commonly Searched Documents
- Opening Doors From a Wheelchair Video
-
11B-609.3 Spacing
grab bars complying with Section 11B-609.9 (Alternate Configuration) the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
11B-609.3 Spacing
grab bars complying with Section 11B-609.9 (Alternate Configuration) the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper...
-
§ 38.155(a)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
4.8.5* HANDRAILS
If a ramp run has a rise greater than 6 in (250 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
-
Head and Back Support (M301.3.3 and M302.3.3)
Where diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated position can be adjusted to reclined positions...
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented along the long dimension of the surface on which patients are positioned in the supine, prone, or side-lying...
-
Maneuvering Space at Doors
Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard....
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view the information shown in Fig. 4, 5, and...
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view information shown in Fig. 4, 5, and 6 in other...
-
Handrails [§504.6, §505]
Handrails [§504.6, §505] Handrails are required on both sides of stairs and must be continuous within the full length of each stair flight....
-
4.9.4 HANDRAILS
Stairways shall have handrails at both sides of all stairs....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm)...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm)...
-
609.3 Spacing
609.3 Spacing. The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches...
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm)...
-
§ 38.95(d) Mobility aid seating location
(d) Mobility aid seating location. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches. Such...