Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
Search Results "Water Closet Clear Floor Space"
Commonly Searched Documents
-
603.2.3 Door Swing
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance....
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
4.7.6 Water Hydrant Clear Floor or Ground Space
Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
Forward Approach: ADA Standard Section 305.7.1
Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach.
-
Parallel Approach: ADA Standard Section 305.7.2
Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach.
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
Clear Floor or Ground Space: ADA Standard Section 902.4.1
A clear floor space complying with 305 positioned for forward approach shall be provided....
- Figure 305.3 Clear Floor or Ground Space – Drawing from the U.S. Access Board
-
Single-User Toilet Rooms: Side Transfer Space
Clear floor space at water closets at least 60 inches wide allows room for side transfers. Lavatories can abut this space (or overlap it as shown on page 89)....
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305....
-
Water Closets [4.16]
Water Closets [4.16] Accessible water closets, including those located in stalls, must comply with the requirements in 4.16....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures" (323...
- Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units – Drawing from the U.S. Access Board
-
General: ADA Standard Section 306.1
Section 306.1 of the ADA Standards covers information in the current ADA Standards for knee and toe clearance.
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. Advisory 11B-1008.4.2 Clear floor or ground space....
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....