233.3.1.2 Facilities Containing Emergency Transportable Housing Units F233.4.1.2 Facilities Containing Emergency Transportable Housing Units These sections contain the scoping requirements...
Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
Commonly Searched Documents
-
233.3.1.2 Facilities Containing Emergency Transportable Housing Units, F233.4.1.2 Facilities Containing Emergency Transportable Housing Units
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
4.21.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
4.21.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
Basic Components for Accessible and Usable Public and Common Use Areas or Facilities
[See subsections ...]
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
Guidelines for Requirement 5
The Guidelines for Requirement 5 present design specifications for providing dwelling units that contain light switches, electrical outlets, thermostats, and other environmental controls...
-
F245.2.1 Picnic Facilities with Two or Fewer Picnic Units
Where picnic facilities contain two or fewer picnic units, each picnic unit shall provide mobility features complying with F245.2....
-
Emergency Transportable Housing: ADA Standard Section 3.
Emergency transportable housing units, which are designed and manufactured for transport over roadways, have a smaller footprint than other types of housing and pose unique accessibility...
-
1012 Parking Spaces Within Camping Units and Picnic Units and Pull-Up Spaces at Dump Stations
[See subsections ...]
-
233.3.6 Dispersion (Exception 2), F233.3.5 Dispersion (Exception 2), F233.4.6 Dispersion (Exception 2)
Residential dwelling units required to provide mobility features complying with 809.2 and residential dwelling units required to provide communication features complying with 809.3 shall...
-
SEC. 104. ILLEGAL USE OF DRUGS AND ALCOHOL. 42 USC 12114
SEC. 104. ILLEGAL USE OF DRUGS AND ALCOHOL. 42 USC 12114.
-
Sec. 12114. Illegal use of drugs and alcohol. [Section 104]
[See subsections ...]
-
11B-608.6 Shower spray unit and water
are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units...
-
Elements Within Picnic Units With Mobility Features [F245.2.5]
At least one of each type of element provided within picnic units with mobility features, including outdoor constructed features and parking spaces, must comply with the applicable technical...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...