It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: The slopes of the undisturbed site...
Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
Commonly Searched Documents
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
-
11B-608.6 Shower spray unit and water
care facilities, transient lodging guest rooms, or residential dwelling units....
-
What occupancies are or are not subject to path of travel and/or accessible routes? …buildings subject to California Building Code (CBC) Chapter 11B? …multi-family buildings subject to CBC Chapter 11A? …others?
RESPONSE: Buildings and facilities required to comply with Chapter 11B, including public housing facilities, are required to comply with the CBC Chapter 11B accessibility provisions for...
-
11B-608.6 Shower spray unit and water
care facilities, transient lodging guest rooms, or residential dwelling units....
-
CCDA Accessibility Checklist for Building Inspectors, 2015 Edition
This Accessibility Checklist is based on the 2013 California Building Code (CBC), Part 2, Title 24, California Code of Regulations and should be used in conjunction with the regulations...
-
4.34.5.4 BATHTUBS
If a bathtub is provided, then it shall have the following features:
-
F245.2.3 Alterations and Additions
Where picnic units are altered or added, the requirements of F245.2 shall apply only to the picnic units that are altered or added until the number of picnic units with mobility features...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
F233.3.1.2 Facilities Containing Emergency Transportable Housing Units
F233.3.1.2 Facilities Containing Emergency Transportable Housing Units This section contains the scoping requirement for emergency transportable housing units with mobility features installed...
-
DSA IR 11B-2: BEVELED LIP AT CURB RAMPS (with revisions issued through Jan. 2011)
(In the 2007 and 2010 CBC this issue has been addressed by removing the requirement for a beveled lip at curb ramps.)...
-
Definition [F106.5]
A camping facility is a site, or a portion of a site, that is developed for outdoor recreational purposes and contains camping units....
-
§ 38.171(c)
(c) Requirements for vehicles and systems not covered by this part shall be determined on a case-by-case basis by the Department of Transportation in consultation with the U.S....
-
28.1 Q. If an architect or builder chooses to follow the bathroom specifications in Requirement 7...are the other bathrooms in the dwelling unit required to have reinforced walls for grab bars?
A. Yes. Requirement 6 of the Guidelines requires reinforced walls in bathrooms for later installation of grab bars. Even though Requirement 6 was not repeated under Requirement...
-
11B-217.4.3.2 Private buildings
Exception: In a stadium or arena, in a convention center, in a hotel with a convention center or in a covered mall, if an interior public pay telephone is provided at least one interior...
-
11B-217.4.3.2 Private buildings
Exception: In a stadium or arena, in a convention center, in a hotel with a convention center or in a covered mall, if an interior public pay telephone is provided at least one interior...
- Symmons Hand Shower T-600B-36-V
- Speakman Versatile Handheld Shower System SM-5040
- Speakman Versatile Thermostatic ADA Handheld Combination System SM-5080-ADA
-
Example 1: With Cooking Facilities
Counter: Compliance not required except as required by 606 for the sink or as required by 804.3 for residential dwelling units. Appliances: Must comply with 804.6....
-
6.2 Entrances
At least one accessible entrance that complies with 4.14 shall be protected from the weather by canopy or roof overhang. Such entrances shall incorporate a passenger loading zone...
-
6.2 ENTRANCES
At least one accessible entrance that complies with 4.14 shall be protected from the weather by canopy or roof overhang. Such entrances shall incorporate a passenger loading zone...