The visible signal elements shall be 2½ inches (64 mm) minimum measured along the vertical centerline of the element....
Search Results "Mitigating Measures"
-
407.2.2.2 Visible Signals
-
404.2.4.3 Recessed Doors and Gates
clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured...
-
Rotational Penetrometer
The penetration into the surface is measured for readings of “firmness.”...
-
On-Site Readers
This is a stop-gap measure which may work when the meeting is short and there is not a large volume of material to be read....
-
11B-221.2.1.5 Stadium-style movie theaters
following criteria: Located within the rear 60 percent of the seats provided in the theater; or Located within the area of the theater in which the vertical viewing angles (as measured...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
19 Inch Low Height
There is a recognized international standard defining various measurements of wheelchairs: ISO 7176-7:1998 Wheelchairs — Part 7: Measurement of seating and wheel dimensions....
-
Americans with Disabilities Act Amendments Act of 2008
measures; (3) to reject the Supreme Court’s reasoning in Sutton v....
- Designing with People
- Access-Able Designs Child Dressing Bench CH-101
- Seton Florida State Parking Signs - Parking By Disabled Permit Only
- VE CONNECT Smart Vending Machine
- Diversified Woodcrafts ADA Compatible Mobile Lab Station with Flat Top 4352KF-RS
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-809.10.6.1 Size
least one shower stall shall comply with one of the following: A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep, clear inside dimensions measured...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. ...
-
2 [§§ 4.7.2; 4.8.2; 4.1.6(3)(a)]
The arrow in the illustration to the left [below], aligned parallel to the ramp run and perpendicular to the curb, shows where to measure the running slope....
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured...
-
11B-221.2.1.5 Stadium-style movie theaters
Located within the area of the theater in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing angles for...
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
Significant Changes – Edge Protection), the final rule requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection, measured...
-
B. Counseling and Prospects for Success
Recipients that operate vocational education programs must insure that counselors do not direct or urge any student to enroll in a particular career or program, or measure or predict a student's...
-
§ 36.303(c)(1)(ii)
should consult with individuals with disabilities whenever possible to determine what type of auxiliary aid is needed to ensure effective communication, but the ultimate decision as to what measures...