Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
Search Results "Maximum Dimension"
-
Height: ADA Standard Section 505.4
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
11B-809.8.4 Door signal devices
The activating mechanism shall be mounted 48 inches (1219 mm) maximum above the floor and connected to permanent wiring....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-809.8.4 Door signal devices
The activating mechanism shall be mounted 48 inches (1219 mm) maximum above the floor and connected to permanent wiring....
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
11B-605.5.1 Urinal location
Urinals in compartments shall have the centerline of the urinal located 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition....
-
11B-605.5.1 Urinal location
Urinals in compartments shall have the centerline of the urinal located 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
Stacks [8.5]
Recommendation: Dimensions for turns around obstructions in 4.3.3 (ADAAG Figure 7) provide minimum space for maneuvering around stacks where a cross aisle at the end of stacks is not provided...
-
11B-405.7.2.1
Handrail extensions are not permitted to obstruct required clear landing dimensions except as allowed by the exception to Section 11B-307.2....
-
4.2 Clear Floor Area
Clear Floor Area (Occupied) Length for All Devices Recent revisions to standards in Australia and the U.K. have increased the clear floor area dimensions in both width and length...
-
Which transition type do users with disabilities prefer?
When a sidewalk slopes more than 2% in the direction of travel and a walk with a maximum 2% cross slope intersects it, which transition segment type provides the safest usability for the...
-
Opening Force
No maximum opening force was proposed for exterior hinged doors....
- Bradley Grab Bars 1 1/2" with Concealed Mounting 812
- Landscape Forms Inc. Max Transportation Stop Shelters
- Door King Inc. 1802 and 1802-EPD Electronic Programmable Directory Telephone Entry System
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
Handrail Gripping Surfaces: ADA Standard Section 1008.2.5.3.1
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....