Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
11B-407.4.1 Car dimensions
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
407.4.1 Car Dimensions
EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and...
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
1134A.6 Showers
Showers required to be accessible shall comply with this section....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
Floor and Ground Surfaces: ADA Standard Section 503.4
Section 503.4 covers the current ADA Standards for the floor and ground surfaces at passenger loading zones.
-
407.4.1 Car Dimensions
EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and...
-
1008.2.4.1 Ground Level
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
1008.2.4.1 Ground Level
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
1008.2.4.1 Ground Level
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum. Exceptions: 1. ...
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum. Exceptions: 1....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
407.4.1 Car Dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
4.8 Outdoor Rinsing Showers
[See subsections ...]
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4....
-
7.4.5 Passing Spaces
Trails with a clear tread width less than 60 inches (1525 mm) shall provide passing spaces complying with 7.4.5 at intervals of 1000 feet (300 m) maximum. ...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
4. Shower Wand
Is there an adjustable height hand-held shower wand with at least a 60" long hose provided so persons who bathe from a seated position may wash and rinse with the directional spray?...