At least one turning space complying with 304.3 shall be provided on fishing piers and platforms....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
Turning Space: ADA Standard Section 1005.5
- Figure 1009.2.2 Pool Lift Seat Location – Drawing from the U.S. Access Board
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Boat Slip Clearance: ADA Standard Section 1003.3.1
Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
11B-411.4.11.3 Duration
Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor....
-
R405.1 General
Where space beneath an element is included as part of a clear space, the space shall comply with R405....
-
11B-806.2.4 Toilet and bathing facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of Sections 11B-603 through 11B-610....
-
11B-304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
11B-304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
Shower Spray Controls
Shower Spray Controls....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
1134A.6 Showers
1134A.6 Showers. Showers required to be accessible shall comply with this section....