Installation of Test Surfaces In accordance with standard EWF design and construction practice (Figure 2), the full depth surfaces were prepared to the same requirements needed for permanent...
Search Results "Maximum Reach Depth"
-
Installation of Test Surfaces
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
Where the 28 inches minimum depth is technically infeasible, the depth may be no less than 21 inches....
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
- Federal Elevator Serenus LULA Elevator
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
704.4.1 Height
wheelchair accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum...
-
704.4.1 Height
wheelchair accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum...
-
704.4.1 Height
wheelchair accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum...
-
b. Positioning Supports
commenters responded: two commenters (disability rights organizations) recommended adding positioning supports; two commenters (manufacturers) recommended providing positioning supports within reach...
-
Database Development
This provides designers and standards developers with in-depth information on the characteristics and functional abilities of certain individuals who present design needs beyond that of...
-
Recessed Lavatories
Where doors swing out, the turning space typically determines the minimum room depth. Lavatories can also be recessed on a side wall....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
1134A.7, Item 1
may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a water closet which extend no more than 24 inches (610 mm) in depth...
-
Clearance Around Base (M301.4.2 and M302.4.2)
The width of the base permitted within this clearance would be 26 inches wide maximum at the edge of the examination surface and is permitted to increase at a rate of 1 inch in width for...
-
605 Urinals
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls....
-
D6. Vestibule Clear Floor Space
Minimum alcove depth of 48 inches if both doors open out Minimum alcove depth of 48 inches + door width when door swings into alcove...
-
Rotational Penetrometer
Firmness was determined by applying a given force to the penetrator and then measuring the depth of penetration into the surface....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm)....
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm)....