Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
-
11B-608.5.1 Transfer type shower compartments
transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum...
-
Location: ADA Standard Section 604.2
Section 604.2 covers the current ADA Standards for the mounting location of water closets.
-
1. Desk size
To provide adequate knee and leg clearance, desks and writing tables need to have at least 30 inches of knee width, 29 inches of knee height, and 19 inches of leg depth....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
Wading Pools
Wading Pools A wading pool is a pool designed for shallow depth and is used for wading. Each wading pool must provide at least one sloped entry into the deepest part....
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
4. c. CUSTOMER SERVICE and COMMUNICATION and ACCESS
Reaching Out to Customers with Disabilities An online ADA course for businesses www.ada.gov/reachingout/intro1.htm A 10-lesson course divided it into individual lesson modules....
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground....
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
4.1.3(17)(a)
At least one public telephone per floor shall meet the requirements for a forward reach telephone3. 1 Additional public telephones may be installed at any height....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
7) Storage and shelves
Self-service shelves and displays must be on an accessible route but need not comply with reach-range requirements (§4.1.3(12))....
- Meeting the Challenge, Inc.
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
M302.2 Transfer Surface
Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth...