In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
Search Results "Door Opening Angle"
Commonly Searched Documents
-
11B-206.5.4 Residential dwelling units
-
11B-206.5.4 Residential dwelling units
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section...
- TownSteel TDG129 Door Guard
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
1132A.8.1 Lever-type hardware
The lever or lever of actuated latches or locks shall be curved with a return to within ½ inch (12.7 mm) of the door to prevent catching on the clothing of persons during egress in Group...
-
§ 38.53(a)(1)
(1) Passenger doorways on vehicle sides shall have clear openings at least 32 inches wide when open....
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
- AD Systems’ Exam Room Doors
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
1.1.9 Horizontal gaps and vertical alignment
1.1.9 Horizontal gaps and vertical alignment. Measure for local horizontal discontinuities and variations in vertical alignment such as at concrete joints, gaps, grade breaks, and at...
-
Inpro Corporation JointMaster® 316 Single Sightline for Carpet Floor Expansion Joint Covers Floor to Floor
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 103 VCT Expansion Joint Systems Floor to Wall
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 300 Recessed Mount Floor Expansion Joint Covers Floor to Wall
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 101 Floor Expansion Joint Covers Floor to Floor
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 103 VCT Expansion Joint Systems Floor to Floor
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 300 Recessed Mount Floor Expansion Joint Covers Floor To Floor
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 101 Floor Expansion Joint Covers Floor to Wall
Requires the Premium User plan or above. (Login or upgrade your account!)