This video is part of a longer animation produced by the U.S. Access Board. View the animation video in its entirety on the Access Board's website...
Search Results "Door Opening Angle"
- Access Board: Accessible Route Openings
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground....
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
-
Problem Four (Entrance)
Problem Four: The entrance door has a door knob and/or latch that requires tight pinching and twisting and is not accessible....
-
Attachment E
Alternatively, on days that the facility is being used as an emergency shelter, keep the interior door propped open....
- BEA Inc. MS08 Door Access Touchless Activation Sensor (Wave to Open)
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
g-ii
Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able to easily...
- Motorized Lift & Slide Door System by Panda
-
Remove post (increase clear width at double leaf doors)
[See subsections ...]