(2) Free-standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...
Search Results "Horizontal Standing Support"
-
4.15.5(2)
-
4.15.5(2)
(2) Free standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...
-
11B-602.10 Bottle filling stations
Exception: Where bottle filling stations are provided at a drinking fountain for standing persons, the bottle filling station is not required to comply with this section provided a bottle...
-
Dispersion Requirements
Like the proposed rule, specifications are provided for horizontal (side to side) and vertical (front to back) dispersion....
-
704.9 Vertical separation of openings
exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm) of each other horizontally...
-
Character Height [4.30.3]
Recommendations: Both the horizontal and vertical viewing distance should be considered....
-
Bathtubs (ADAAG 4.20)
Moreover, frail older adults usually have the ability to stand....
-
3.3.2 Experienced Clinicians
Because exam chairs have up-right back support, armrests, and patients do not typically need to reposition their entire body once on the equipment, a narrower minimum width of 21” is proposed...
-
Lifting Capacity
Lifting Capacity Lifts must have the capability of supporting a minimum weight of 300 pounds and be capable of sustaining a static load that is at least 1.5 times the rated load....
-
E203.2 User Needs
How users with disabilities will perform the functions supported by the ICT; and B....
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
11B-602.6 Water flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
11B-602.6 Water flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
4.9.3 Nosings
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
4.9.3 NOSINGS
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
§ 38.23(b)(10) Platform movement
The maximum platform horizontal and vertical acceleration when occupied shall be 0.3g....
-
§ 38.125(b)(10) Platform movement
The maximum platform horizontal and vertical acceleration when occupied shall be 0.3g....