1. Faucets: Faucet handles or controls need to be usable with one loosely closed fist, because some people with disabilities can use only one hand and cannot grasp or twist faucets....
Search Results "Lavatory Clear Floor Space"
-
1. Faucets
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space. Figure 1009.4.3 Depth and Length of Transfer Walls...
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space. FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS...
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space. Figure 1009.4.3 Depth and Length of Transfer Walls...
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted....
-
11B-307.5 Required clear width
Protruding objects shall not reduce the clear width required for accessible routes....
-
11B-307.5 Required clear width
Protruding objects shall not reduce the clear width required for accessible routes....
-
11B-403.2 Floor or ground surface
Floor or ground surfaces shall comply with Section 11B-302....
-
11B-403.2 Floor or ground surface
Floor or ground surfaces shall comply with Section 11B-302....
-
Accessibility of Facilities
◼ New twin-aisle aircraft must have accessible lavatories....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
1134A.8 Lavatories, vanities, mirrors and towel fixtures. Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory....
-
Turning Space: ADA Standard Section 1005.5
At least one turning space complying with 304.3 shall be provided on fishing piers and platforms....
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
1134A.5, Item 1
The edge of the clear floor space shall be flush with the control wall surface....
-
1134A.5, Item 1
The edge of the clear floor space shall be flush with the control wall surface....
-
R405.1 General
Where space beneath an element is included as part of a clear space, the space shall comply with R405....
-
11B-411.4.11.3 Duration
Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor....
-
11B-411.4.11.3 Duration
Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor....