A clear floor space allowing a person using a wheelchair to make a 180-degree turn shall be provided in every accessible dressing room entered through a swinging or sliding door....
Search Results "Lavatory Clear Floor Space"
-
4.35.2 Clear Floor Space
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
-
Clear Deck Space
Clear Deck Space Clear deck space must be provided to enable a person to get close enough to the pool lift seat to easily transfer from a wheelchair or mobility device....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
4.32.2 Seating
If seating spaces for people in wheelchairs are provided at fixed tables or counters, clear floor space complying with 4.2.4 shall be provided....
-
4.32.2 SEATING
If seating spaces for people in wheelchairs are provided at tables, counters, or work surfaces, clear floor space complying with 4.2.4 shall be provided....
-
304.2 Floor or Ground Surfaces
304.2 Floor or Ground Surfaces. Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted....
-
Technical Memorandum TM 2013-14 Dining Surfaces
This includes, but is not limited to; seating and standing spaces provided at fixed or built-in tables, bars, lunch counters, and booths....
-
802.1.1 Floor or Ground Surface
802.1.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted....
-
Clearance
Wider clearances are specified for wheelchair passing space (60 inches minimum) and certain sharp turns around narrow obstructions....
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space. Figure 1009.4.3 Depth and Length of Transfer Walls...
- Figure 1009.2.2 Pool Lift Seat Location – Drawing from the U.S. Access Board
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space. FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS...
-
9. Faucet Control
Does the lavatory in each accessible guestroom bathroom have a faucet that is easily operable (i.e.: levers, wrist blades, single arm, etc.) and usable with one hand, without tight grasping...
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space. Figure 1009.4.3 Depth and Length of Transfer Walls...