In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
Search Results "Lavatory Clear Floor Space"
-
11B-1009.2.2 Seat location
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
809.2.6 Weather Alert Systems
in emergency transportable housing units, this section requires the operable parts on weather alert systems in units with mobility features to comply with the technical requirements for clear...
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
Plan 2A: 13-Foot Wide Accessible Guest Room
); • Recessed roll-in shower location permits shorter rear grab bar at water closet (section 604.5.2); • Clear floor space adjacent to shower min. 30 inches wide by 60 inches long...
-
§ 38.57(b)
route at least 32 inches wide so that at least two wheelchair or mobility aid users can enter the vehicle and position the wheelchairs or mobility aids in areas, each having a minimum clear...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.19.1 General
The requirements of 4.19 shall apply to lavatory fixtures, vanities, and built-in lavatories....
-
4.19.1 GENERAL
The requirements of 4.19 shall apply to lavatory fixtures, vanities, and built-in lavatories....
-
Passing Space [§403.5.3]
Passing Space [§403.5.3] Passing space is required every 200 feet and must be provided as a 60” by 60” minimum space or as T-shaped space where each stem is at least 48” long....
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Clear Width [1016.3]
The clear width of ORARs must be a minimum of 36 inches....
-
Design Opportunity
clearance at 27" AFF under the vanity top (306) while keeping the counter/rim at 34" AFF maximum (606.3); and it may require more than 8" minimum knee clearance to provide the extended depth clear...
-
Platform and Vehicle Floor Coordination: ADA Standard Section 810.5.3
Advisory 810.5.3 Platform and Vehicle Floor Coordination....
-
Plan 6B: 12-Foot Wide Accessible Guest Room
(section 607.2); • Recessed lavatory with vanity counter top permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1);...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
Additional benefits of water closet clearance standards
The standards requiring sufficient space in single-user toilet rooms for a wheelchair user to effect a side or parallel transfer are among the most costly (in monetary terms) of the new...
-
Additional benefits of water closet clearance standards
The standards requiring sufficient space in single-user toilet rooms for a wheelchair user to effect a side or parallel transfer are among the most costly (in monetary terms) of the new...