A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
Search Results "Dwelling (FHA)"
Commonly Searched Documents
-
11B-809.10.5.1 Clear floor space
-
Example 1: With Cooking Facilities
Counter: Compliance not required except as required by 606 for the sink or as required by 804.3 for residential dwelling units. Appliances: Must comply with 804.6....
-
804.3 Kitchen Work Surface (Exception)
804.3 Kitchen Work Surface (Exception) This section requires at least one work surface to be provided at kitchen counters in residential dwelling units required to provide mobility features...
-
1.1.7.3.1 Detached one- and two-family dwellings
Detached one- and two-family dwellings, lodging houses, live/work units, townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
233 Residential Facilities
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units that are subject...
-
11B-224.7 Housing at a place of education
Exception: Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or...
-
11B-224.7 Housing at a place of education
Exception: Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
606.2 Clear Floor Space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
Common Use Areas in Residential Facilities—Section 203.8 of the 2010 Standards
Section 203.8 of the 2010 Standards provides that, in residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features are not...
-
11B-603.2.3 Door swing
SECTION TITLE NOTES 11B-603.2.3 Door swing. Clarifies that doors to accessible toilet compartments are...
-
4.34.5.7 CLEAR FLOOR SPACE
Clear floor space at fixtures may overlap.
-
Structural Impracticability—28 CFR 35.151
Under § 35.151(a)(2) full compliance with the requirements of the 2010 Standards is not required in new construction where a public entity can demonstrate that it is structurally...
-
11B-224.7 Housing at a place of education
Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
-
606.2 Clear Floor Space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
606.2 Clear Floor Space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2. Doors to small...
-
11B-206.2.3 Multi-story buildings and facilities
through 11B-809.4, residential dwelling units with adaptable features complying with Chapter 11A, Division IV, all common use areas serving residential dwelling units with mobility features...
-
11B-206.2.3 Multi-story buildings and facilities
through 11B-809.4, residential dwelling units with adaptable features complying with Chapter 11A, Division IV, all common use areas serving residential dwelling units with mobility features...
-
11B-206.2.3 Multi-story buildings and facilities
through 11B-809.4, residential dwelling units with adaptable features complying with Sections 11B-809.6 through 11B-809.12, all common use areas serving residential dwelling units with...