5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
Search Results "Dwelling (FHA)"
-
1132A.3, Item 5
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section. 1. Floor space and location. The minimum floor space provided at a water...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
608.4 Seats (Exception)
An exception to the section permits seats to not be installed in transfer type shower compartments in residential dwelling units required to provide mobility features provided that the walls...
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment...
-
8. A condominium (or apartment) development has to comply only with CBC Chapter 11A.
The California Fair Employment and Housing Act (FEHA) requires all "covered multi-family dwellings" designed and constructed for first occupancy after March 13, 1991 to be readily accessible...
-
206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
-
F206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
-
206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
-
11B-216.8.1 Geometric symbols
Such spaces include but are not limited to; patient sleeping rooms, transient lodging guest rooms, and residential dwelling units....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
The following may only be used for determining required access to multifamily dwelling units, in a single building with one common (lobby) entrance, located on a site with difficult terrain...
-
11B-216.8.1 Geometric symbols
Such spaces include but are not limited to; patient sleeping rooms, transient lodging guest rooms, and residential dwelling units. 2. ...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.