5.8.2.7 Base Support Allowance. Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½...
Search Results "Patient in Side-Lying Position"
Commonly Searched Documents
-
5.8.2.7 Base Support Allowance
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground. The knee clearance should be increased at 27 inches above the ground to 18 inches minimum.
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground The Committee recommends increasing the knee clearance at 27 inches above the ground to 18 inches minimum.
-
5.8.2.4 Unobstructed Floor Space
5.8.2.4 Unobstructed Floor Space. The unobstructed floor space in front of the base support should be a minimum of 17 inches deep.
-
5.8.3.1 Breast Platform Height
5.8.3.1 Breast Platform Height. The height of the top of the breast platform should be decreased to 26 inches above the floor. The upper height range for the breast platform was not...
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
5.8.2.8 Knee and Toe Clearance Recommendations Summary Ultimately, all of the knee and toe clearance recommendations in sections 5.8.2.1 – 5.8.2.7 are summarized below, in Figure...
-
5.8.2.6 Clearance Depth at Toe Height Above the Ground
5.8.2.6 Clearance Depth at Toe Height Above the Ground. The toe clearance depth should be 22 inches minimum at toe height.
-
5.8.3 Breast Platform
5.8.3 Breast Platform
-
5.8.2.3 Overall Knee and Toe Clearance Recommendation
5.8.2.3 Overall Knee and Toe Clearance Recommendation The Committee recommends increasing the overall knee and toe space to 28 inches minimum. Rationale for the...
-
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation The Committee recommends 22 inches minimum clearance depth at toe height. Rationale for...
-
5.8.2.3 Overall Knee and Toe Clearance
5.8.2.3 Overall Knee and Toe Clearance. The overall knee and toe space should be increased to a minimum of 28 inches.
-
Figure M6: M303.2.4 Knee and Toe Clearance
[See subsections ...]
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
2. c. REACH RANGES
Figure 18 (high forward reach range), and Figure 19 (side reach range) illustrate reach ranges accessible to wheelchair users or people with limited mobility....
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level landings each side...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level landings each side...
-
3. Exception to Ramp Running Slope
The Access Board agrees with the MDE Advisory Committee that additional allowances in the slope of ramp runs of diagnostic equipment used by patients seated in a wheelchair with raised platforms...
-
A4.27.3 Height
Fig. A8 further illustrates mandatory and advisory control mounting height provisions for typical equipment. Electrical receptacles installed to serve individual...
-
3.5.3 Signs in General
If materials need to be obtained from or manipulated on a sign or kiosk, the sign or kiosk shall be designed to meet the reach ranges in section 308 of the ABAAS.
-
11B-411.2.1.3.4 Position
Display screens and touch screens shall be positioned so glare is reduced on the screen. Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
- Just Manufacturing 42" Stainless Steel Grab Bar
- Bobrick 42" Straight Grab Bar Peened B-6806.99 x 42
- Bobrick 42" Straight Grab Bar Peened B-5806.99 x 42