Built-Up Curb Ramp with Side Flares Recommendations: Provide edge protection along the sides of built-up curb ramps to prevent tipping hazards....
Search Results "Patient in Side-Lying Position"
Commonly Searched Documents
-
Built-Up Curb Ramps
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
(1)(c)
(c) A grab bar at least 24 inches (610 mm) long should be mounted behind the water closet, and a horizontal grab bar at least 40 inches (1015 mm) long should be mounted on at least one side...
- Bobrick Two-Wall Toilet Compartment Grab Bar B-5897
- Bobrick Two-Wall Toilet Compartment Grab Bar B-6897
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-5897.99
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-6897.99
- Defining and Delivering Disability-Competent Care - The Individualized Plan of Care
- Defining and Delivering Disability-Competent Care - Managing Transitions
- Defining and Delivering Disability-Competent Care - Preparing for New Roles & Responsibilities, Participant And Provider Readiness
- Defining and Delivering Disability-Competent Care - Providing Disability-Competent Primary Care
- Defining and Delivering Disability-Competent Care - Flexible Long Term Services and Supports
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
Ramps with drop offs ½ inch or greater shall provide edge protection 2 inches high minimum on each side....
-
Imaging bed
A component of diagnostic scanning equipment that accommodates patients in supine, prone, or side-lying positions....
-
4.34.3(2)(b) Reach Depth More Than 10 in
(b) Reach Depth More Than 10 in (255 mm). Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed...
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
(a) Reach Depth Not More Than 10 in (255 mm). Where the reach depth to the operable parts of all controls as measured from the vertical plane perpendicular to the edge of the...
-
A4.27.3 HEIGHT
Fig. A6 further illustrates mandatory and advisory control mounting height provision for typical equipment. Note distinction between built-in equipment (considered real property) and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum. EXCEPTION: Wheelchair spaces located on raised platforms shall be permitted to be 32 inches (815 mm) wide minimum to a...
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.2.4 Equipment Clearances
Where wheelchair spaces are entered from the rear and includes space beneath components, wheelchair spaces shall include knee and toe clearances complying with M303.2.4.1 for breast...
-
M303.3.2 Beveled (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required...