In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
Search Results "Patient in Side-Lying Position"
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door. In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
-
M303.2.2 Width (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients seated in a wheelchair provide a wheelchair space that was at least 36 inches wide....
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- 308.3.1 Automatic Trash Can Height
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from the...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
407.4.8.1.1 Size
Characters shall be ½ inch (13 mm) high minimum.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. [ECTCR UFAS 4.10.13] EXCEPTION: For elevators other than...
-
Audible Tones/Bells or Verbal Annunciators
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors? [ADA Stds. 4.10.13] Yes __ No __ N/A __ Comments:...
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. EXCEPTION: For elevators other than destination-oriented elevators...