Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
Search Results "Patient in Side-Lying Position"
Commonly Searched Documents
-
11B-308.3.2 Obstructed high reach
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
223.1.1 Alterations
As a facility is altered over time, every effort should be made to disperse accessible sleeping rooms among patient care areas such as pediatrics, cardiac care, maternity, and other units...
-
F223.1.1 Alterations
As a facility is altered over time, every effort should be made to disperse accessible sleeping rooms among patient care areas such as pediatrics, cardiac care, maternity, and other units...
-
223.1.1 Alterations
As a facility is altered over time, every effort should be made to disperse accessible sleeping rooms among patient care areas such as pediatrics, cardiac care, maternity, and other units...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door. In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
- Figure 604.5.1 Side Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
- 308.3.1 Automatic Trash Can Height
-
5.8.3 Breast Platform Recommendations
platform (see 5.8.2 Knee and Toe Clearance Recommendations under Breast Platforms), the height of the breast platform is also critical to ensuring that mammography equipment is accessible to patients...
-
Wall furr-out to support a grab bar when toilet is too far from the side wall
Here's a good example of one solution for a water closet that's too far from the adjacent side wall. ...
-
11B-407.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. Exception: For elevators that have a rated speed of 200 feet per...
-
407.4.8.1.1 Size
Characters shall be ½ inch (13 mm) high minimum.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. [ECTCR UFAS 4.10.13] EXCEPTION: For elevators other than...
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. EXCEPTION: For elevators other than destination-oriented elevators...
-
407.4.8.1.1 Size
Characters shall be 1/2 inch (13 mm) high minimum.
-
407.4.8.1.1 Size
407.4.8.1.1 Size. Characters shall be ½ inch (13 mm) high minimum.
-
Audible Tones/Bells or Verbal Annunciators
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors? [ADA Stds. 4.10.13] Yes __ No __ N/A __ Comments:...
-
407.4.8.2.1 Signal Type
407.4.8.2.1 Signal Type. The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. EXCEPTION: For elevators other than...