In large rooms and spaces exceeding 100 ft (30 m) across, without obstructions 6 ft (2 m) above the finish floor, such as auditoriums, devices may be placed around the perimeter, spaced...
Search Results "Finished Grade"
Commonly Searched Documents
-
4.28.3(7)
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
to Section 11B-306.3.3, Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish...
-
Updates and Other Pocket Guides
We are currently finishing additional Pocket Guide versions covering selected state access standards. ...
-
Accessible Entrance
The area adjacent to the landing is graded flush with the landing so no drop-off exists between the landing and the grass area eliminating the need for railings....
-
Slopes and Resting Intervals for Beach Access Routes
Running slope, also referred to as "grade," is the lengthwise slope of a beach access route, parallel to the direction of travel....
- DORMA 8600 Series Door Closer
-
Slope [§405.2] and Cross Slope [§405.3]
Variations in slope, such as grade breaks within runs, can disrupt wheelchair travel....
-
REFERENCES
uniform statewide criteria for plan review and construction inspection of projects within the jurisdiction of DSA which includes State of California public elementary and secondary schools (grades...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
602.2 Clear Floor Space
(2), Fig. 27(c), Fig. 27(d)] EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish...
-
Tips for Communicating with Individuals with Speech Impairments
Do not speak for the individual or attempt to finish her or his sentences....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
502.6 Identification
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. Advisory 502.6 Identification....
-
Signs
Signs that provide direction to, or information, about functional spaces must only comply with requirements for character proportion, character height, and finish and contrast between the...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....