The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
Search Results "Covered Multifamily Dwelling (FHA)"
Commonly Searched Documents
-
11B-809.10.7.1 Floor space
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-233.3.1.2.6.4 Test number three, unusual characteristics test
Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-708.4.1 Common use or public use system interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
233.1 General
In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3. 2....
-
409.1 General
Private residence elevators that are provided within a residential dwelling unit required to provide mobility features complying with 809.2 through 809.4 shall comply with 409 and with ASME...
-
Question 21
YES/NO 21. Are all the accessible dispensers in the public restrooms filled?
-
F202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Architectural Barriers Act or Section 504 of the Rehabilitation Act of 1973,...
-
202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to Texas Government Code, Chapter 469, shall not be required to comply with 202.3....
-
11B-233.2 Reserved
[2010 ADAS] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations. ...
-
11B-233.2 Reserved.
[2010 ADAS] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
11B-233.2 Reserved
[2010 ADA Standards] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Americans with Disabilities Act or Section 504 of the Rehabilitation Act of...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
1133A.4, Item 3
3. Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components. Exception: Two 15-inch (381 mm) wide minimum...
-
1132A.3, Item 1
1. Doors shall not be less than 6 feet 8 inches (2032 mm) in height.
-
1133A.2.1, Item 1
1. U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm). (See...
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(1) The lavatory and mirrors shall comply with 4.22.6. (2) If a cabinet is provided under the lavatory in adaptable bathrooms, then it shall be removable to provide the clearances...
-
1132A.3, Item 1
1. Doors shall not be less than 6 feet 8 inches (2032 mm) in height.
-
1133A.2.1, Item 1
1. U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm). (See...
-
1133A.4, Item 3
3. Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components. Exception: Two 15-inch (381 mm) wide minimum...
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...