Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with F229. 2....
Search Results "Covered Multifamily Dwelling (FHA)"
Commonly Searched Documents
-
F229.1 General
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
Section 35.151(e) Social service center establishments
First, for the first time, residential dwelling units are explicitly covered in the 2004 ADAAG in section 233....
-
11B-229.1 General
Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229. 2. ...
-
11B-233.1 General
Strictly privately-owned single-family dwellings are not covered by Chapter 11B; however, certain privately-owned facilities, either single-family or multi-family, that provide housing on...
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 18 inches (457 mm) minimum from the water closet centerline where...
-
Alterations to Residential Facilities
Applying the general requirements for alterations to housing can result in partially accessible dwelling units where single elements or spaces in dwelling units are altered....
-
Other Boxes: ADA Standard Section 221.2.1.3
Section 221.2.1.3 covers scoping requirements in the current ADA Standards for wheelchair spaces at other boxes not covered under 221.2.1.3.
-
809.2.2 Turning Space
809.2.2 Turning Space. All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces...
-
1133A.2, Item 3
3. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required...
-
1132A.4.1 Thresholds
1132A.4.1 Thresholds. Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm). Thresholds at secondary exterior doors, including sliding door...
-
1131A.2 Changes greater than ½ inch
1131A.2 Changes greater than ½ inch. Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units...
-
1131A.1 Changes in level not exceeding ½ inch
1131A.1 Changes in level not exceeding ½ inch. Abrupt changes in level along any accessible route shall not exceed ½ inch (12.7 mm). When changes in level do occur, they shall be...
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
809.2.2 Turning Space
All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm)...
-
809.2.2 Turning Space
All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm)...
-
1132A.4, Item 1
1. Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7...
-
1133A.4, Item 2
2. A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface.
-
1133A.3 Removable base cabinets
1133A.3 Removable base cabinets. Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with a knee and toe space complying with...
-
Parking at Residential Facilities
Parking at Residential Facilities