Exception: In residential dwelling units, seats shall not be required in shower compartments provided that reinforcement has been installed in walls so as to permit the installation of seats...
Search Results "Covered Multifamily Dwelling (FHA)"
-
11B-608.4 Seats
-
11B-608.4 Seats
Exception: In residential dwelling units, seats shall not be required in shower compartments provided that reinforcement has been installed in walls so as to permit the installation of seats...
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.8.2 Door opening force
Doors shall comply with Section 11B-404.2.9. Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
Other Boxes: ADA Standard Section 221.2.1.3
Section 221.2.1.3 covers scoping requirements in the current ADA Standards for wheelchair spaces at other boxes not covered under 221.2.1.3.
-
229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2....
-
229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2....
-
F229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with F229. 2....
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
Section 35.151(e) Social service center establishments
First, for the first time, residential dwelling units are explicitly covered in the 2004 ADAAG in section 233....
-
11B-229.1 General
Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229. 2. ...
-
11B-233.1 General
Strictly privately-owned single-family dwellings are not covered by Chapter 11B; however, certain privately-owned facilities, either single-family or multi-family, that provide housing on...
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
Alterations to Residential Facilities
Applying the general requirements for alterations to housing can result in partially accessible dwelling units where single elements or spaces in dwelling units are altered....
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 18 inches (457 mm) minimum from the water closet centerline where...
-
809.2.2 Turning Space
809.2.2 Turning Space. All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces...
-
1133A.2, Item 3
3. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required...
-
1132A.4.1 Thresholds
1132A.4.1 Thresholds. Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm). Thresholds at secondary exterior doors, including sliding door...