Residential dwelling units required to provide mobility features complying with 809.2 and residential dwelling units required to provide communication features complying with 809.3 shall...
Search Results "Multistory Dwelling Unit (FHA)"
Commonly Searched Documents
-
233.3.6 Dispersion (Exception 2), F233.3.5 Dispersion (Exception 2), F233.4.6 Dispersion (Exception 2)
-
1134A.6, Item 1
When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following requirements....
-
1134A.6, Item 1
When one or more shower stalls are provided within the same dwelling units, at least one shower stall shall comply with one of the following requirements....
-
1012 Parking Spaces Within Camping Units and Picnic Units and Pull-Up Spaces at Dump Stations
[See subsections ...]
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
11.1 Q. Under the individual building test, how is the second step of the test performed, which involves measuring the slope of the finished grade between the entrance and applicable arrival points?
A. The slope is measured at ground level from the entrance to the top of the pavement of all vehicular and pedestrian arrival points within 50 feet of the planned entrance, or, if...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work...
-
1133A.7, Item 1
1. The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided.
-
1133A.7, Item 1
1. The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided.
-
1133A.2, Item 4
4. The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space,...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
Elements Within Picnic Units With Mobility Features [F245.2.5]
At least one of each type of element provided within picnic units with mobility features, including outdoor constructed features and parking spaces, must comply with the applicable technical...
-
Washing Machines; Clothes Dryers— Sections 214.2 and 214.3 of the 2010 Standards
UFAS requires front loading washing machines and clothes dryers in common use laundry rooms in facilities serving accessible residential dwelling units.20 UFAS’ requirements for front-loading...
- Symmons Allura® Tub/Hand Shower System S-4704
- American Standard Colony Soft Diverter & Personal Trim Kit
- Speakman Versatile ADA Handheld Shower System SM-5490-ADA
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 _|Private Residence Elevators|_ shall be permitted in multi-story residential dwelling units....
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 _|Private Residence Elevators|_ shall be permitted in multi-story residential dwelling units....