4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater...
Search Results "Multifamily Dwelling (HUD 504)"
Commonly Searched Documents
-
1134A.7, Item 4
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The...
-
1134A.8, Item 7
7. Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are...
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may...
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
-
1134A.6, Item 1.2
1.2. The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may project...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are designed...
-
1134A.7, Item 4
4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5...
-
1150A.1 General
Covered multifamily dwellings in buildings without an elevator, located on sites with difficult terrain conditions or unusual characteristics, may employ the site impracticality tests in...
-
1150A.1 General
Covered multifamily dwellings in buildings without an elevator, located on sites with difficult terrain conditions or unusual characteristics, may employ the site impracticality tests in...
-
§8.26 Distribution of accessible dwelling units.
Accessible dwelling units required by §8.22, 8.23, 8.24 or 8.25 shall, to the maximum extent feasible and subject to reasonable health and safety requirements, be distributed throughout...
-
1134A.7 Water closets
1134A.7 Water closets. Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section. 1. Floor space and location. The minimum floor space provided at a water...
-
11B-233.2 Reserved
[2010 ADA Standards] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations
233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
Covered Multifamily Dwellings
The Department has revised the definition of "covered multifamily dwellings" to clarify that dwelling units within a single structure separated by firewalls do not, for purposes of these...
-
1134A.4 Sufficient maneuvering space
1134A.4 Sufficient maneuvering space. Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other...
-
1134A.8, Item 4.3
4.3. Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. The knee and toe space shall be centered...