SECTION 1134A BATHING AND TOILET FACILITIES
-
1134A.6, Item 4
4. Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor. The grab...
-
1134A.8, Item 4.1
4.1. The space beneath the lavatory shall be left clear and unobstructed;
-
1134A.8, Item 4.2
4.2. Any cabinet beneath the lavatory shall be removable without the use of specialized knowledge or specialized tools; or
-
SECTION 1134A BATHING AND TOILET FACILITIES
[See subsections ...]
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units. Repositionable countertops shall comply with the following:...
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units. Repositionable countertops shall comply with the following:...
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
1134A.8 Lavatories, vanities, mirrors and towel fixtures. Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory. Where mirrors and towel...
-
1134A.6, Item 2
2. Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum or...
-
1134A.5, Item 2
2. Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars. Where a...
-
1134A.6, Item 6
6. Shower controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units...
-
1134A.8, Item 5
5. Finished floor. The finished floor beneath the lavatory shall be extended to the wall.
-
1134A.7, Item 2
2. Reinforced walls for grab bars. Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for...
-
1134A.5, Item 2
2. Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars. Where a bathtub is...
-
1134A.6, Item 6
6. Shower controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.6, Item 2
2. Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum or...
-
1134A.8, Item 5
5. Finished floor. The finished floor beneath the lavatory shall be extended to the wall.
-
1134A.8, Item 7
7. Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal...