Door openings shall provide a clear width of 32 inches (813 mm) minimum....
Search Results "End-Opening Door"
Commonly Searched Documents
-
11B-404.2.3 Clear width
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
R302.7.3 Horizontal Openings
R302.7.3 Horizontal Openings. Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 mm (0.5 in) in diameter....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
Door Swing: ADA Standard Section 603.2.3
Section 603.2.3 covers the current ADA Standards for door swings at clear floor space and clearances at fixtures in toilet and bathing rooms.
-
Restrooms Main Lobby
The restroom vestibule door does not have the required minimum of 18" maneuvering clearance on the latch side of the door. See Standards § 4.13.6. l....
-
Operation: ADA Standard Section 407.3.2
Section 407.3.2 covers the current ADA Standards for elevator door operations.
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Manual Doors and Gates [§404.2]
Manual Doors and Gates [§404.2]...