Search Results "End-Opening Door"
-
4.13.11(2)(a)
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force. ...
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADA Standards] 404.2.9 Door and Gate Opening Force....
-
Open Risers: ADA Standard Section 504.3
Section 504.3 covers the current ADA Standards for open risers on stairways.
-
d. i.
Provide doors that require no more than 5 lbf to push or pull open at the following locations: (1) Spy City Café men's and women's toilet rooms; (2) Main Lobby restrooms vestibule;...
-
Door and Signal Timing: ADA Standard Section 407.3.4
Section 407.3.4 covers the current ADA Standards for door and signal timing of elevator reopening devices.
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
E. Door Pressure
Door Pressure (1) Defendants will perform door force checks on all public access doors and will adjust or modify as necessary to ensure that they do not require more than five (5) pounds...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
4.13.11(2)(b)
(b) interior hinged doors: 5 lbf (22.2N)...
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
-
A4.13.11(3) Application of force
(3) Application of force: Apply force gradually so that the applied force does not exceed the resistance of the door....
-
OPEN RISER
[DSA-AC] The space between two adjacent stair treads not closed by a riser.
-
OPEN RISER
[DSA-AC] The space between two adjacent stair treads not closed by a riser.
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
11B-604.8.1.1.2 Maneuvering space with side-opening door....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Measuring Opening Force
Measuring Opening Force The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door...
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
4.13.11(2)(c)
(c) sliding or folding doors: 5 lbf (22.2N) These forces do not apply to the force required to retract latch bolts or disengage other devices that may hold the door in a closed position...
-
4.13.11(1)
(1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....