Search Results "Drinking Fountain"
-
Plumbing/Restrooms
-
Plumbing/Restrooms
Restroom symbols on door 11B-703.7.2.6 Shower compartments 11B-608 Bathtubs 11B-607 Drinking...
-
Primary Function Areas [4.1.6(2)]
area containing a primary function, an accessible "path of travel" is required which means a continuous route connecting the altered area to an entrance, including phones, restrooms, and drinking...
-
Guidelines for Requirement 2
include, for example: accessible route(s); protruding objects; ground and floor surface treatments; parking and passenger loading zones; curb ramps; ramps; stairs; elevator, platform lifts; drinking...
-
4.15 Drinking Fountains and Water Coolers
-
4.15 DRINKING FOUNTAINS AND WATER COOLERS
-
4.15.1 MINIMUM NUMBER
Drinking fountains or water coolers required to be accessible by 4.1 shall comply with 4.15....
-
4.15.1 Minimum Number
Drinking fountains or water coolers required to be accessible by 4.1 shall comply with 4.15....
-
4.15.2* SPOUT HEIGHT
Figure 27 Drinking Fountains and Water Coolers...
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a)).
-
4.15.3 SPOUT LOCATION
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
-
4.15.3 Spout Location
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
-
4.15.4 CONTROLS
Controls shall comply with 4.27.4. Unit controls shall be front mounted or side mounted near the front edge.
-
4.15.4 Controls
Controls shall comply with 4.27.4. Unit controls shall be front mounted or side mounted near the front edge.
-
4.15.5 CLEARANCES
-
4.15.5 Clearances.
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
4.15.5(2)
(2) Free standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a...
-
4.15.5(2)
(2) Free-standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a...
-
Drinking Fountains and Water Coolers [4.15]
Drinking Fountains and Water Coolers [4.15] Drinking fountains and water coolers accessible to people who use wheelchairs may be too low for people with a limited ability to bend or stoop...
-
Plumbed Fixtures
Plumbed Fixtures ADAAG covers fixed units where they are provided. Fixed units are not required over units that are not fixed. Where non-fixed units are provided instead,...
-
Scoping [4.1.3(10)]
Scoping [4.1.3(10)] ADAAG does not specify the number of fixtures a building must have. Instead it requires access based on the number provided on each floor so that half (50%)...
-
One Unit Per Floor
Cup dispensers at fixed units are not recommended but if provided for dual access, the drinking fountain should be wheelchair accessible....