Exterior Sites Recommendation: The 50% scoping required for building interiors should be followed for exterior sites. Where only one unit is provided or where they are spaced at...
Search Results "Drinking Fountain"
-
Exterior Sites
-
Dispersion
Dispersion Recommendation: Wheelchair accessible units and standard units should be evenly dispersed to maximize convenient availability. For example, if a floor is occupied by...
-
Standard Units
Standard Units Units at conventional heights for use by standees are considered accessible to people who may bend or stoop with difficulty. It is important that cantilevered units...
-
Spout Location [4.15.3]
Spout Location [4.15.3] A person using a wheelchair has limited ability to lean over a drinking fountain, especially from a side approach....
-
Controls [4.15.4]
Controls [4.15.4] Controls must be operable with one hand and not require tight grasping, pinching, or twisting of the wrist to operate. Push bars are easier to use by a broader...
-
Forward Approach
Forward Approach Drinking fountains are easier to use from a forward approach than from a side approach. Clearances for a forward approach are required at cantilevered units....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in. Space must be available so that a person using a wheelchair can align...
-
602 Drinking Fountains
-
602.1 General
Drinking fountains shall comply with 307 and 602....
-
Additions: ADA Standard Section 202.2
Section 202.2 covers the most current requirements for additions in existing building and facilities.
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit. Knee and toe clearance complying with 306 shall be...
-
602.3 Operable Parts
Operable parts shall comply with 309.
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground.
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers.
-
602.6 Water Flow
The purpose of requiring the drinking fountain spout to produce a flow of water 4 inches (100 mm) high minimum is so that a cup can be inserted under the flow of water to provide a drink...
-
602.7 Drinking Fountains for Standing Persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
-
Drinking Fountains: ADA Standard Section 211
Section 211 covers scoping requirements in the current ADA Standards for drinking fountains....
-
General: ADA Standard Section 211.1
Section 211.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for drinking fountains....
-
Minimum Number: ADA Standard Section 211.2
Section 211.2 covers scoping requirements in the current ADA Standards for the minimum number of drinking fountains that are required....
-
More Than Minimum Number: ADA Standard Section 211.3
Section 211.3 covers scoping requirements in the current ADA Standards for when there are more than the minimum number of drinking fountains provided....
-
Drinking Fountain Water Flow Tool
Drinking Fountain Water Flow Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring drinking fountain water flow....
-
602 Drinking Fountains
602 Drinking Fountains...
-
III-6.2000 Alterations: Path of travel
The "path of travel" requirement includes an accessible route to the altered area and the bathrooms, telephones, and drinking fountains serving the area....
-
602.1 General
Drinking fountains shall comply with 307 and 602....