The walking surface on steps serving all other non-rail vehicle doorways shall be lighted at all times with 2 foot-candles (22 lux) minimum of illumination.
Search Results "Door"
-
T503.4 Steps at Other Doorways
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Exterior lighting shall be provided to illuminate walking surfaces of boarding and alighting areas when the doors of non-rail vehicles are open....
-
4.3.9 DOORS
Doors along an accessible route shall comply with 4.13....
-
4.3.9 Doors
Doors along an accessible route shall comply with 4.13....
-
T504 Passenger Access Routes
-
404 Doors, Doorways, and Gates
404 Doors, Doorways, and Gates...
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
Components of Accessible Routes
-
404.2 Manual Doors, Doorways, and Manual Gates
404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
4.13 DOORS
-
4.13 Doors
-
4.13.1 General
Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
-
4.13.1 GENERAL
Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
-
4.13.11* DOOR OPENING FORCE
The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
4.13.11(2)(a)
(a) exterior hinged doors: (Reserved)....
-
Doors [4.13]
-
Scoping [4.1.3(7)]
Scoping [4.1.3(7)] Doors required to be accessible include: at least one door at each accessible entrance at least one door at each accessible space within a building...
-
4.22.2 Doors
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
4.23.2 Doors
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
-
4.23.2 DOORS
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....