Accessible - Changes in Level: Changes in level up to 1/4" may be vertical and without edge treatment....
Search Results "Changes in Level"
Commonly Searched Documents
-
Accessible - Changes in Level
-
1.2.4
1.2.4 When local horizontal discontinuities and vertical alignments are measured according to Section 1.1.9 a recommended tolerance is ±1/8 in. (3 mm).
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303....
- Figure 303.2 Vertical Change in Level – Drawing from the U.S. Access Board
- Figure 303.3 Beveled Change in Level – Drawing from the U.S. Access Board
-
G2
Is the accessible route free of steps and abrupt level changes over 1/2 inch? Yes No Note: level changes between 1/4 inch and 1/2 inch should be beveled)....
-
11B-405.7.1 Slope
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
B. Accessible Route
Is there a route to these 5% accessible fixed tables that allows at least 36" clear width and has no abrupt vertical level changes greater than 1/4"?...
-
Ground Level: ADA Standard Section 1008.2.5.1
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
Changes in Level - Door Thresholds Tool
Changes in Level - Door Thresholds Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring door thresholds and level changes....
-
Changes in Level - Accessible Route Tool
Changes in Level - Accessible Route Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring changes in level along an accessible route....
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
Thresholds at Doorways [4.13.8]
Negotiating level changes while simultaneously resisting the force of closers can be difficult....
-
1131A.2 Changes greater than ½ inch
1131A.2 Changes greater than ½ inch. ...
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
11B-249 Adult changing facilities
[See subsections ...]
-
11B-404.2.4.4 Floor or ground surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exceptions: Reserved....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
E1-2. Accessible Route
Is the accessible route free of steps and abrupt level changes over 1/2 inch (level changes between 1/4 inch and 1/2 inch should be beveled)?...
-
E1-b
Is the accessible route free of steps and abrupt level changes over 1/2 inch? Yes No Note: level changes between 1/4 inch and 1/2 inch should be beveled)....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....