The route must be free of abrupt changes in level, steps, high thresholds, or steeply sloped walkways....
Search Results "Changes in Level"
-
Accessible Routes (Exterior and Interior)
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2....
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with 404.2.5....
-
305.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
T302 Walking Surfaces
technical requirements for walking surfaces include provisions on slip resistance, the maximum size of surface openings, and the maximum height of vertical surface discontinuities (i.e., changes...
-
Exterior Routes
Openings in floor or ground surfaces 1/2 inch maximum with long dimension perpendicular to direction of travel. 11B-302.3 Vertical change...
-
Exterior Routes
Openings in floor or ground surfaces 1/2 inch maximum with long dimension perpendicular to direction of travel. 11B-302.3 Vertical change...
-
Interior Routes
slopes at walking surfaces and ramps. 11B-403.3 11B-405 Handrails on ramps and stairways. 11B-505 Vertical change...
-
Interior Routes
slopes at walking surfaces and ramps. 11B-403.3 11B-405 Handrails on ramps and stairways. 11B-505 Vertical change...
-
502.4 Floor or Ground Surfaces
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
303 Changes in Level
-
Where Ramps and Curb Ramps are Required [§303.4]
Where Ramps and Curb Ramps are Required [§303.4] Ramps and curb ramps are required along accessible routes to span changes in level greater than ½”....
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2....
-
303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. Figure 303.2 Vertical Change in Level...
-
303.3 Beveled
A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....
-
503.4 Floor and Ground Surfaces
Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
403.4 Changes in Level
403.4 Changes in Level. Changes in level shall comply with 303....
-
303.4 Ramps
Changes in level greater than ½ inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
4.3.8 Changes in Levels
Changes in levels along an accessible route shall comply with 4.5.2....
-
4.3.8 CHANGES IN LEVELS
Changes in levels along an accessible route shall comply with 4.5.2....